LDV System 3-Component
Request a Quote
Accessories
Related Products
Required Components
Product Details
The pre-configured typical three-component (3D) LDV system is used to get all three components of velocity, simultaneously. The fiberoptic transceiver probes offer point-and-shoot velocity measurement capability, with large 61 mm collection apertures. The probes are attached to convenient rotating mounts for easy setup. Alignment devices are included for obtaining high coincident data rates. Processing electronics have been pre-selected and configured for a wide range of velocity measurements.
The LDV measuring point can be traversed using an optional traverse system. The traverse, running under software control, can automatically move the measuring point while optimally selecting the system operating parameters at each location. This provides a fully automated, optimized measurement system for mapping the flow field.
Features and Benefits
- All system components are included
- Easy-to-use FLOWSIZER™ Data Acquisition and Analysis Software is included
- High-power water cooled laser included
- Sturdy mounts and rail system included
Applications
- Wind tunnels
- Turbulence measurements
- Water channels
- Non-contact velocity measurements
- Measurements in combustion, flame, rotating machinery
Included Items
- 5 Watt argon ion laser
- FBL-3 fiberlight™ Multicolor Beam Generator and six couplers
- TR160-13 One-Component Fiberoptic Transceiver Probe
- TR260 Two-Component Fiberoptic Transceiver Probe
- PDM1000-3 Three-channel Photodetector Module
- FSA 3500-3 Signal Processor
- FLOWSIZER Software Package
- Mounting and alignment hardware
- Manuals
- Accessory kits and mounting hardware
To learn more about LDV instrumentation and the many areas of research this system is involved in, attend TSI's Fluid Mechanics Webinar Series presented by our experts.
FAQs
What is the difference between focal length and focal distance of a lense?
Focal distance refers to the distance from the front of the lens to the beam crossing point (see figure). To define the focal length, the lens is replaced by a line, AB. The positon of the vertical line is such that the two parallel beams are deflected, as shown in the figure, so that the two beams cross. The distance measured from this line AB to the focal point is referred to as the focal length of the lens. For the case of a thin lens (thickness of the lens/focal length is small), the value of focal length and focal distance are almost the same. For the case of a thick lens, the location of the line AB will be noticeably different from the front of the lens. Hence, the focal length and focal distance will differ.
What is the relationship between the velocity component measured and the frequency (Doppler) of the signal?
The component of velocity that lies in the plane of the beams and normal to the bisector of the two laser beams of a dual-beam system is measured by an LDV system. From the following figure, the component of velocity measured is uy.If 2kappa is the angle between the two beams, the fringe spacing, df for the dual beam LDV system is:df = lambda / (2 sin kappa)where lambda is the wavelength of light.If fD is the Doppler frequency of the signal generated by the passage of a particle with velocity u (see figure) through the measuring volume:fD = uy / dfHence, the frequency of the Doppler signal is proportional to velocity.