Additional Product Info

TrakPro Data Analysis Software

Request A Quote Related Products

Product Details

TrakPro™ Data Analysis Software is a Windows®-based software program that works with a variety of TSI data logging instruments. This unique software helps you pre-program instruments, store and organize your test data, and generate detailed graphs and reports needed to effectively communicate results.

The TrakPro™ software program is included free with every Q-Trak™ Plus IAQ Monitor, SidePak™ Personal Aerosol Monitor, SidePak™ SP730 OR SP530 Personal Sampling Pumps, DustTrak™ Aerosol Monitor, AeroTrak™ 9000 Nanoparticle Aerosol Monitor, and P-Trak® Ultrafine Particle Counter. This package is a truly integrated software tool for many health and safety measurement applications.

TrakPro™ software is the ideal tool for indoor air quality studies, exposure studies or environmental monitoring. It allows you to view, organize, analyze and save data quickly and efficiently. Easily download data from any of these instruments and generate detailed graphs and reports.

Data from any of the instruments can be overlapped for a truly comprehensive picture of test results. Users can select from a wide range of presentation formats and can configure TSI instruments, including such functions as date, time and logging parameters. 

Features and Benefits 

  • Display data in color or black and white, in tabular or graphical form
  • Combine multiple data sets into a single graph for comparison
  • Define and upload data logging protocols for unattended Q-Trak™, SidePak™, DustTrak™, AeroTrak®, or P-Trak® monitor operation
  • Enter and upload calibration factors for the DustTrak™ and SidePak™ AM510 monitors
  • Create template files and merge with SidePak™ Sampling Pump history files to create detailed reports
  • Export data to other software

Computer Requirements 

  • TrakPro v.4.5.0 and later: Microsoft Windows® XP (32-bit only), or Windows® 7 (32-bit or 64-bit) operating systems
  • TrakPro v.3.62 and later: Microsoft Windows® XP, 2000 operating systems
  • TrakPro v.3.41: Microsoft Windows® XP, 2000, Me, NT®, 98 operating systems 
  • RS-232 serial port (for Q-Trak™, DustTrak™ and P-Trak® only)
  • USB port (for all SidePak™ and AeroTrak® instruments)

FAQs
  • Can we copy the software for use on other computers?
    Yes. The software is copyrighted, but may be copied to enable use of TSI products with several computers.
  • I'm not a computer expert. What is the easiest way to understand the TrakPro software?
    TrakPro software includes example data files. These files contain test examples useful for learning how the software operates independent of the instrument.
  • What are the computer requirements for TrakPro Data Analysis Software?
    Microsoft Windows® XP (32-bit only) or 7 (32-bit or 64-bit) operating systems.
  • What changes are associated with TrakPro version 3.40?
    Incorporated support for TSI’s SidePak™ Model SP530 and SP730 Sampling Pumps.Added a “Set User Calibration” option for the SidePak AM510, to allow the user to set the current calibration from TrakPro™ software as well as the instrument keypad.The date format was made more flexible. It is now possible to change the date format by changing the Regional Settings in the Windows Control Panel.A help file was added to assist in installing USB drivers.Upgraded to ProEssentials v4 graphics DLL. This will slightly affect the appearance of TrakPro graphs, while allowing for future features. 
  • What changes are associated with TrakPro version 3.41?
    Incorporated support for the Model 8592 Air Velocity Probe as an auxiliary sensor for the Q-Trak™ Plus IAQ Monitor. This change includes special graphing functions and test data views for face velocity and volumetric flow rate measurements.
  • What changes are associated with TrakPro version 3.62?
    Added support for the AeroTrak® 9000/8220/8240/8260 Monitor
  • What does the TrakPro™ Data Analysis Software allow me to do?
    TrakPro™ Data Analysis Software has numerous functions: Download (receive) stored data from the Q-Trak™ Plus IAQ Monitor, DustTrak™ Aerosol Monitor, ProtectAir™ Multi-gas Monitor, and P-Trak® Ultrafine Particle Counter data logger. Store test data to disk. Display data in table or graphical form. Send table or graphical information to a monochrome or color printer. Combine multiple data sets into a single graph for comparison purposes. Up to six channels of data may be presented from tests run at the same time or at different times. Create graph titles, annotate graphs, change scales. Print graphs on monochrome or color printers. Export data to other database or spreadsheet software via comma-delimited ASCII data file. Set date and time functions in the Q-Trak Plus monitor, DustTrak monitor, ProtectAir monitor, and P-Trak counter. Alter the selection of logging intervals and time constants available for Log 1 in the Q-Trak Plus monitor/DustTrak monitor/P-Trak counter. Define & upload data logging protocols (log 2 & log 3) used by the Q-Trak Plus monitor/DustTrak monitor/P-Trak counter for unattended operation.
  • What is the cost of the TrakPro software?
    TrakPro Data Analysis Software is provided at no additional charge.

If you are seeing this, then the pnlEUCookieScripts is working