MASS FLOWMETERS FOR LABORATORY AND GENERAL PURPOSE APPLICATIONS

MASS FLOWMETERS FOR LABORATORY AND GENERAL PURPOSE APPLICATIONS

TSI 4000/4100 Series Mass Flowmeters are designed for a multitude of gas flow measurement applications. Whether measuring gas flows in a laboratory or manufacturing setting, TSI general-purpose mass flowmeters provide accurate results with multiple data output options. The display versions come complete with accessories making setup and operation fast and convenient.

The TSI mass flowmeters sensors are specified as 2% of reading. One TSI mass flow sensor covers the same range as three or more "percent of full scale devices" ... with better accuracy at most points!

Fast 4 millisecond response ensures accuracy in fluctuation flows. This fast response time of the TSI mass flowmeter is ideal for closed-loop control systems and integrated volume measurements.

Low pressure drop of the TSI mass flowmeter minimizes flow circuit back pressure and its impact on the system.

Features and Benefits

  • Accuracy of 2% of reading (not full scale)
  • Multi-gas, user-selectable
  • Fast 4 millisecond response to changes in flow
  • Very low pressure drop
  • RS 232 interface
  • Voltage output of flow rate
  • Measure flow rate, temperature, and pressure (display unit only)
    in one instrument

Applications

  • Research and product development
  • Quality assurance
  • Product testing
  • Metrology
  • Medical
  • Environmental
  • OEM

40211

TSI Mass Flow Sensor Model 40211: FlowMeter, 300L/min, Air, 22mm tube

 

40212

TSI Mass Flow Sensor Model 40212: FlowMeter, 300L/min, O2, 22mm tube

 

40241

TSI Mass Flow Sensor Model 40241: FlowMeter, 300L/min Air 3/4" Tube

 

40242

TSI Mass Flow Sensor Model 40242: FlowMeter, 300L/min O2 3/4" Tube

 

40246

TSI Mass Flow Sensor Model 40246: FlowMeter, 200L/min N2 3/4" Tube

 

4040

TSI Mass FlowMeter with LCD, 300L/min Air,O2,N2 22mm Tube

 

4043

TSI Mass FlowMeter with LCD, 200L/min Air,O2,N2 1/2" Tube

 

4045

TSI Mass FlowMeter with LCD, 300L/min Air,O2,N2 3/4" Tube

 

41211

TSI Mass Flow Sensor: FlowMeter, 20L/min Air 1/4" Tube Model 41211

41212

TSI Mass Flow Sensor: FlowMeter, 20L/min O2 1/4" Tube

41213

 TSI Mass FlowMeter: 20L/min N2O 1/4" Tube

 

41216

TSI Mass Flow Sensor: FlowMeter, 20L/min N2 1/4" Tube

41221

TSI Mass Flow Sensor: FlowMeter, 20L/min Air 3/8" Tube

41222

TSI Mass Flow Sensor: FlowMeter, 20L/min Oxygen 3/8" Tube

41226

TSI Mass FlowMeter, 20L/min N2 3/8" Tube

 

4140

TSI Mass Flowmeter, 20L/min Air, O2, N2 1/4" Tube

 

41403

TSI Nitrous Oxide Flowmeter: FlowMeter with LCD, 20L/min N2O, Air, O2, N2 1/4" Tube

 

4143

Mass flowmeter with LCD, 20L/min, Air, O2, N2, 3/8" Tube

 

41433

TSI Nitrous Oxide Flowmeter 41433: FlowMeter with LCD, 20L/min, N2O, Air, O2, N2, 3/8" tube

 

There are currently no items for this section.

SERVICE INFORMATION

APPLICATION NOTES

 Correcting for Humidity Effects on TSI General Purpose Flow Meters
 FLOW-Cerfiticate of Calibration for 4000 and 4100 Series Flowmeters
 Measuring Volumes with Gas Mass Flow Sensors
 Reverse Flow Effects on TSI General Purpose Flowmeters
 Standard Flow Rate vs. Volumetric Flow Rate
 TSI Mass Flowmeters Theory of Operation
 Using HyperTerminal® to communicate with TSI Flowmeters

MANUALS

 Model 4040/4043/4045
 Model 4140/4143
 Model 4199 Battery Pack for Series 4000/4100
 Modell 4140/4143 Betriebs- und Wartungshandbuch
 Serie 4000/4100 RS232 Serielle Schnittstelle RS232 Serial Command Set
 Series 4000/4100 Design Guide
 Series 4000/4100 RS232 Serial Command Set

QUICK GUIDES

 TSI Flow Operating Hints

SOFTWARE

 Flowmeter Set-up Program (Version 1.2)
 Real-time Demo Program (Version 1/19/00)
 Source Code for Real-time Demo Program (Version 8/29/00)

FREQUENTLY ASKED QUESTIONS

show/hide all answers
  1. Are the flowmeters bi-directional?
  2. Are there any special connection requirements for the analog output?
  3. Are there correction factors for these different gasses?
  4. Are these flowmeters pressure compensated?
  5. Are these flowmeters temperature compensated?
  6. Can I change the scaling of the analog output signal?
  7. Can I clean the sensor in my flowmeter?
  8. Can I measure flow in both directions through my flowmeter?
  9. Can I operate my flowmeter in any orientation?
  10. Can I slow down the response of the analog output signal?
  11. Do I need to filter the gas going into my flowmeter?
  12. Does humidity affect my readings?
  13. How can I configure the flowmeter’s options?
  14. How do I connect my flowmeter using the two cables supplied?
  15. How do I recalibrate my flowmeter?
  16. How do these flowmeters measure volume?
  17. How often should I recalibrate my flowmeter?
  18. I need to develop custom software using LabView® to interface with the TSI flowmeter. What help is available?
  19. Is there an RS-232 interface available on the flowmeter?
  20. Please explain NIST traceability
  21. What about other gasses and mixtures?
  22. What are some applications for which these flowmeters are NOT designed?
  23. What are some typical applications for these flowmeters?
  24. What are some typical industries that use these flowmeters?
  25. What are the available outputs of flow data?
  26. What are the available outputs of pressure data?
  27. What are the available outputs of temperature data?
  28. What are the available outputs of volume data?
  29. What are the special features of these flowmeters?
  30. What data is available from the analog output?
  31. What is the accuracy and range of the temperature measurement?
  32. What is the difference between “% of reading” and “% of full scale” accuracy specifications?
  33. What is the difference between Standard Flowrate and Volumetric Flowrate?
  34. What is the flow accuracy of the flowmeters?
  35. What is the range and accuracy of the pressure measurement?
  36. What is the range of the analog output signal?
  37. What is the range of volume measurement?
  38. What is the response of the pressure measurement?
  39. What is the response of the temperature measurement?
  40. What is the response time of the flow measurement?
  41. What software do I need to configure the flowmeter’s options?
  42. Where is the pressure tap located?
  43. Which gasses can I measure?