PIV SYSTEM 2D

PIV SYSTEM 2D

Particle image velocimetry (PIV) systems measure the instantaneous global velocity field in a flowing fluid. Since introducing the first commercial PIV system in 1988, TSI has led the way in PIV innovation and technology. Our 2D PIV system maintains this tradition by incorporating the most advanced analysis schemes in a completely re-engineered software platform built for flexibility and expansion. Features such as grid deformation, the patented Hart and Rohaly-Hart correlation algorithms, and other algorithms from our exclusive license to MicroPIV technology such as ensemble correlation averaging and background correction, ensure the highest possible measurement accuracy even in sparsely seeded flows and flows with large spatial velocity gradients.

Features and Benefits

  • Grid deformation for high accuracy measurements even in the presence of large spatial velocity gradients
  • On-line measurement and display of velocity field
  • Patented analysis algorithms such as the Hart and Rohaly-Hart Correlations
  • Ensemble correlation averaging, dynamic background correction, and other proprietary algorithms stemming from our exclusive licence of microPIV technology

Applications

  • Design optimization in flow devices
  • Fluid mechanics research
  • Validation of CFD result

Included Items

  • Double pulse Nd:YAG laser (50mJ/pulse standard, higher pulse energy available as upgrade option)
  • CCD camera with frame-straddling (specific model depends upon application; includes camera lens, all interface cables, camera frame grabber)
  • INSIGHT™ 3G-2DTR Data Acquisition, Analysis and Display Software Package
  • Light sheet optics (and optional Laser Light Arm)
  • Optical filter
  • LASERPULSE™ Synchronizer (Model 610034 or 610035, depending upon application)
  • All associated manuals

 

To learn more about PIV instrumentation and the many areas of research this system is involved in, attend TSI's Fluid Mechanics Webinar Series presented by our experts. Visit www.tsi.com/FMwebinars.

Computer for PIV

TSI Computers integrate the latest advances in computer technology, including processing and memory storage, in order to provide the fastest, most flexible PIV and/or PLIF system available.

INSIGHT™ 3G-2DTR Software Package

INSIGHT™ 3G-2DTR software package process PIV image capture, analysis and display software on .NET platform

INSIGHT™ 3G-GLOBAL Software Package

INSIGHT™ 3G-Global software package process Stereo PIV, PLIF and Global Spray image capture, analysis and display software on .NET platform

INSIGHT™ 3G-PIVSPR Software Package

INSIGHT™ 3G-PIVSPR software package processes PIV and Global Spray image capture, analysis and display software on .NET platform

INSIGHT™ 3G-SPR Software Package

INSIGHT™ 3G-SPR software package processes Global Spray image capture, analysis and display software on .NET platform.

Laser - YAG120-15

TSI LASERPULSE Mini-YAG Laser Model YAG120-BSL

Laser - YAG200-15

TSI LASERPULSE YAG Laser Model YAG190-BSL

Laser - YAG30-15

TSI LASERPULSE Mini-YAG Laser Model YAG30-15

Laser - YAG50-15

TSI LASERPULSE Mini-YAG Laser Model YAG50-15

LASERPULSE Synchronizer Model 610035

The LASERPULSE Synchronizer Model 610035 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications.

LASERPULSE™ Light Arm

TSI’s LASERPULSE Light Arm is an articulated arm that offers flexibility in delivering the light sheet for PIV measurements or for other high energy laser applications.

LASERPULSE™ Synchronizer Model 610034

The LASERPULSE Synchronizer Model 610034 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications.

Light Sheet Optics

Laser light sheet optics from TSI provide flexibility in the light sheet divergence angle and the beam waist location via careful selection of focal lengths. for PIV and PLIF applications.

MicroPIV Optical Lens Assembly Model 610048

The TSI Model 610048 MicroPIV Optical Lens Assembly is designed for PIV measurements in small flow regions.

Microscope System

TSI Model 660000 microscope is the key component for the TSI microPIV system. The microscope is equipped with the epi-fluorescent optics to allow illumination and collection of image signal from the same optical path.

POWERVIEW™ 1.4MP Camera

 TSI's POWERVIEW™ 1.4MP Camera offers 1376 × 1040 pixel resolution and 12-bit intensity dynamic range, short frame straddling times, and long exposure times for PIV and PLIF applications.

POWERVIEW™ Plus 11MP Camera

TSI POWERVIEW™ Plus 11MP Camera is a multi-bit, 11-megapixel, digital CCD camera designed exclusively for global flow measurements.

POWERVIEW™ Plus 2MP Camera

TSI POWERVIEW™ Plus 2MP Camera is a multi-bit, 2-megapixel, digital CCD camera designed exclusively for global flow measurements.

POWERVIEW™ Plus 4MP Camera

TSI POWERVIEW™ Plus 4MP Camera is a multi-bit, 4-megapixel, digital CCD camera designed exclusively for global flow measurements.

POWERVIEW™ Plus HS-200 Camera

POWERVIEW™ Plus HS-200 Camera has 640 × 480 pixel resolution, 12-bit intensity dynamic range, along with high image capture rates up to 500 frames per second.

Filters

TSI offers a full range of optical filters, which are a critically important component of PIV and PLIF system, ensuring that the correct wavelength of light is collected by the CCD camera and that other wavelengths are rejected.

Laser Power Meters

TSI Laser Power Meters provide a convenient and accurate way to measure Ar ion beam powers, to keep your LDV or PDPA system running at peak efficiency.

Laser Safety Glasses

TSI Laser Laser Safety Goggles provide a solid protection from direct and scattered laser beams. We take the guesswork out of selection and purchase of Ar ion, YAG, and YLF safety eyewear, so you can focus on using the system.

MicroPIV Optical Lens Assembly

The TSI Model 610048 MicroPIV Optical Assembly is designed for PIV measurements in small flow regions. Typically, it is used when making velocity measurements in small channels or flow devices with dimensions of the order of 1 mm or smaller.

Mount Kits for PIV

TSI's PIV Mount Kits provide a user-friendly and rugged but precise mounting base for your PIV camera(s). Easy adjustment and long-term stability are the key features of the TSI PIV Mount Kits.

Oil Droplet Generator

The Oil Droplet Generator (TSI Model 9307) is used to produce large quantities of oil droplets for seeding flows when making PIV or LDV measurements. The large droplet output is especially useful for seeding high-speed flows.

Rails for PIV

TSI Rails provide the flexibility in a sturdy support system needed for any PIV system. Various lengths are available, to customise the system to the cameras and light sheet optics used.

Remote Focus Mechanism

TSI Model 640050/1-R series of Remote Focus Mechanism provides the remote and precise adjustment of camera focusing tot he measurement plane in PIV/PLIF measurements

Seed Particles

TSI offers a full range of seed particles to satisfy even the most difficult measurement requirements. Available in a full range of materials and sizes, TSI seed particles maximize the potential of PIV and LDV systems.

Single-jet Atomizer

TSI's Model 9302 single-jet atomizer generates a polydisperse aerosol stream from a compressed air source. External pressure control and a flexible outlet tube allow the user to put the right amount of aerosol right where its needed.

Six-jet Atomizer

The Six-Jet atomizer from TSI is used to generate a polydisperse aerosol in high concentrations, which can be used as seed particles for PIV and LDV measurements. External controls adjust the number of active jets and dilution air flow rate.

Traverse Accessories for PIV

Traverse accessories help the user get the most productivity out of their TSI traverse, while enhancing safety of operation.

Traverse System - 1-Axis Traverse System

Single Axis (1D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. These traverses are also used for capturing size and velocity profiles in a flow with a FLOWSIZER™

Traverse System - 2-Axis Traverse System

 TSI T2D and T2DE Two Axis (2D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis System.

Traverse System - 3-Axis Heavy-Duty Traverse System

Three Axis (3D) Heavy-duty Traverse Systems are used for capturing size and velocity profiles in a flow with a three-component FLOWSIZER™ software-based LDV or phase Doppler system.

Traverse System - 3-Axis Long Traverse System

Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with TSI INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems.

Traverse System - 3-Axis Traverse System

Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems.