PDPA SYSTEM 2-COMPONENT

PDPA SYSTEM 2-COMPONENT

This pre-configured two-component PDPA system gets you up and running in a hurry. It is a workhorse system providing maximum two-component size and velocity data with minimum hardware. The fiberoptic transmitter probe allows a multitude of fringe spacings and beam waist sizes when optional beam expander and focusing lenses are used. The 110 mm RV 70 series receiver probe is our most popular unit. Both probes are attached to convenient rotating mounts for easy setup. Processing electronics have been pre-selected and configured for a wide range of size and velocity measurements.

This system can be upgraded to a three-component PDPA system. Since traversing, seeding, and data processing requirements will vary with the application, no traverses, particle generators, or computer is included here.

Features and Benefits
  • All system components are included
  • Easy-to-Use FLOWSIZER™ Data Acquisition and Analysis Software is included
  • System offers good mid-range capabilities
  • Can be used as a starting point for more advanced capabilities
  • Powerful water-cooled laser included
Applications
  • Spray measurements
  • Droplet size measurement
  • Detailed size and velocity measurements
  • Size-velocity correlation
  • Spray characterization
Included Items
  • LA70-2 Coherent 2W Argon-Ion Laser
  • FBL-2 fiberlight™ Multicolor Beam Generator with Four Fiberoptic Couplers
  • TM250 Two-component Fiberoptic Transmitter (70 mm diameter)
  • RV2070 Two-component Fiberoptic Receiver (110 mm diameter)
  • PDM1000-2P Two-channel Photodetector Module
  • FSA3500-2P Two-channel Signal Processor for Velocity and Size
  • Manual
  • Accessory kits

 

To learn more about PDPA instrumentation and the many areas of research this system is involved in, attend TSI's Fluid Mechanics Webinar Series presented by our experts. Visit www.tsi.com/FMwebinars.

 

Argon-Ion Laser 300mW

The LA-300 Argon Ion Laser provides the best combination of laser power and versatility for an entry-level air cooled laser for LDV and phase Doppler systems.

Argon-Ion Laser 5W

The LA-70-5 and LA-90-5 Argon Ion Lasers offer the best performance for advanced two and three componant LDV and phase Doppler systems.

Argon-Ion Laser LA-70-2

The LA-70-2 Argon Ion Laser provides the best combination of laser power and stability for an entry-level water cooled laser for LDV and phase Doppler systems.

Computer Model 6390A

A high performance Personal Computer (PC) to ensure compatibility and performance with the LDV/PDPA system.

Fiberlight™ Multi-Color Beam Generator 2-Component

TSI Model FBL-2 fiberlight™ Multicolor Beam Generator provides high power handling capacity in a compact easy-to-align package. Two beam pairs are generated, and four fiber couplers are provided.

FLOWSIZER™ Data Acquisition & Analysis Software

TSI’s FlowSizer™ data acquisition, analysis, and display software is a simple-to-use yet comprehensive interface between the components of the LDV or PDPA system and the user.

Multi-bit Digital Burst Correlators for Velocity and Size Model FSA 3500-P

TSI's FSA 3500-P offers sampling rates to 400 MHz and 8-bit analog-to-digital conversion (ADC) and thrives on high speed and low SNR flow situations.

Multi-bit Digital Burst Correlators for Velocity and Size Model FSA 4000-P

TSI Multi-bit Digital Processor Model FSA 4000P offers h-end capabilities like 50ns minimum transit time and 175 MHz maximum input frequency.

Probe - Fiberoptic Receiver Probe 106mm

The 106mm Fiberoptic Receiver Probe's optical aperture allows collection of signals even from small droplets in dense sprays, at long stand-offs, and even with reduced laser power.

Probe - Fiberoptic Receiver Probe 72mm

RV 70 Series phase Doppler Receiver with optimized optical design for the most reliable phase Doppler measurements over the widest dynamic range.

Probe - Transceiver Probe 83mm Diameter 2-Component

The TR260 transceiver probe is our most popular two-component LDV probe. Easy to set up and use, it operates in the backscatter mode, with receiving optics built in.

Probe - Transmitting Probe 70mm

The TM series transmitting probes are used for phase Doppler measurements. They are compact, user-friendly, and provide a wide variety of fringe spacings and waist sizes. They are equipped with a convenient rotating mount and sliding base.

External Input

TSI External Input Card Model EB  allows input of up to 4 channels of analog data, including the once-per-rev(OPR) signal.

External Input Card Module

The External Input Card module allows input of four analog and one once-per-rev (OPR) signal, plus up to four channels of digital data, all using a convenient interface box with Status Light, BNCs, and D-Sub connectors.

Hardware Kits for PDPA

Hardware Kits for PDPA provide the rugged but precise mounting structure needed for today's PDPA systems. Fast setup and long-term stability are the key features of the TSI PDPA Hardware Kits.

Laser Power Meters

TSI Laser Power Meters provide a convenient and accurate way to measure Ar ion beam powers, to keep your LDV or PDPA system running at peak efficiency.

Laser Safety Glasses

TSI Laser Laser Safety Goggles provide a solid protection from direct and scattered laser beams. We take the guesswork out of selection and purchase of Ar ion, YAG, and YLF safety eyewear, so you can focus on using the system.

Monosize Droplet Generator

The MDG100 produces a stream of uniform size drops in the range of 50um to 300um. It relies upon an established technique of liquid column excitation to generate the droplet stream.

Mount Kits for PDPA

Mount Kits for PDPA provide the rugged but precise mounting base needed to get the maximum performance from PDPA systems. Easy adjustment and long-term stability are the key features of the TSI Mount Kits.

Oil Droplet Generator

The Oil Droplet Generator (TSI Model 9307) is used to produce large quantities of oil droplets for seeding flows when making PIV or LDV measurements. The large droplet output is especially useful for seeding high-speed flows.

Polarization Axis Finder

The 10901A Polarization Axis Finder is a unique tool that provides instant indication of a laser beam's polarization axis. No twisting or turning is required.

Rails for PDPA

TSI Rails provide the most flexible and sturdy support system for any PDPA system. Various lengths are available, to customise the system to the probes and focal lengths used.

Seed Particles

TSI offers a full range of seed particles to satisfy even the most difficult measurement requirements. Available in a full range of materials and sizes, TSI seed particles maximize the potential of PIV and LDV systems.

Single-jet Atomizer

TSI's Model 9302 single-jet atomizer generates a polydisperse aerosol stream from a compressed air source. External pressure control and a flexible outlet tube allow the user to put the right amount of aerosol right where its needed.

Six-jet Atomizer

The Six-Jet atomizer from TSI is used to generate a polydisperse aerosol in high concentrations, which can be used as seed particles for PIV and LDV measurements. External controls adjust the number of active jets and dilution air flow rate.

Traverse Accessories for PDPA

Traverse accessories help the user get the most productivity out of their TSI traverse, while enhancing safety of operation.

Traverse System - 1-Axis Traverse System

Single Axis (1D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. These traverses are also used for capturing size and velocity profiles in a flow with a FLOWSIZER™

Traverse System - 2-Axis Traverse System

 TSI T2D and T2DE Two Axis (2D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis System.

Traverse System - 3-Axis Heavy-Duty Traverse System

Three Axis (3D) Heavy-duty Traverse Systems are used for capturing size and velocity profiles in a flow with a three-component FLOWSIZER™ software-based LDV or phase Doppler system.

Traverse System - 3-Axis Long Traverse System

Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with TSI INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems.

Traverse System - 3-Axis Traverse System

Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems.

Turning Mirror Sets