PLIF SYSTEM COMBUSTION MEASUREMENT
The TSI Global Combustion Species Analyzer (GCSA) is designed to meet the research needs of anyone needing a fully integrated system that provides global species measurements in mixing, materials processing, heat/mass transfer, and combustion environments. GCSA uses planar laser-induced fluorescence (PLIF) to provide global concentration measurement of specific species of interest in the laser sheet region. The system consists of three integrated sub-systems: the Illumination System, the Imaging System, and the Display and Analysis System. The GSCA system was designed not only to satisfy your immediate research needs, but also to facilitate future expansion to perform additional measurements as your research objectives evolve. The Illumination System is an integrated unit that includes a Nd:YAG laser, dye laser to provide tunable wavelength control from 420 nm to 750 nm, and frequency doubling unit to extend the wavelength range from 217 nm to 750 nm. The Imaging System is ideal for fluorescence measurements in vapor phase environments, featuring a CCD camera with internal intensifier capable of very short gate times (down to 3 ns) in order to capture short-lived fluorescence signals, to increase the low signal levels of trace-level species, and to limit the influence of extraneous light sources such as flame luminosity. The system is fully integrated into a single unit through the revolutionary Insight 3G Global Imaging software platform, which not only provides data analysis and display capabilities, but also directly controls the hardware components for simple system operation. The system is easily expandable to allow the measurement of additional species. Fluorescence filters are available for common species such as OH, CH, and Formaldehyde. Common GCSA measurements include species measurements, fuel distribution or concentration mapping, and flame front detection. The user can switch between these by installing the appropriate optical camera filter, and in some cases switching to a different laser dye.
features and benefits
- Provides global measurements of scalar quantities such as pH and species
- Advanced analysis algorithms to account for camera noise, background signals, spatial variations in laser sheet intensity, temporal variations in laser pulse energy
- User-programmable image analysis schemes for maximum experimental flexibility
- Full range of camera support, including all TSI intensified and un-intensified cameras
- Seamless integration with TSI PIV systems for simultaneous global velocity measurements
- Excitation wavelength flexibility from UV into IR
applications
- Combustion diagnostics
- Combustion analysis
- Species measurements
 |
TSI Dye lasers for PLIF offer a high energy output at the lines you need, and include many features that make them easier to use than other dye lasers. |
 |
TSI External Image Intensifiers allow flexible use of your PowerView Plus series camera. Easily attachable and fully integrated into the Insight 3G software package, this image intensifier allows a wider variety of PLIF and Micro-PIV measurements. |
 |
INSIGHT™ 3G-PIVLIF software package processes PIV and PLIF image capture, analysis and display software on .NET platform. |
 |
INSIGHT™ 3G-Global software package process Stereo PIV, PLIF and Global Spray image capture, analysis and display software on .NET platform
|
 |
INSIGHT™ 3G-LIF software package processes PLIF Image Capture, analysis and display software on .NET platform. |
 |
TSI Image Intensified Cameras are the best way to extract data from weak fluorescence and tight timing measurement situations. Fully integrated into the Insight 3G software package, these cameras allow a variety of PLIF and other Global Imaging measurements to be made. |
 |
The LASERPULSE Synchronizer Model 610035 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications. |
 |
TSI offers a full range of optical filters, which are a critically important component of PIV and PLIF system, ensuring that the correct wavelength of light is collected by the CCD camera and that other wavelengths are rejected. |
 |
TSI Laser Power Meters provide a convenient and accurate way to measure Ar ion beam powers, to keep your LDV or PDPA system running at peak efficiency. |
 |
TSI Laser Laser Safety Goggles provide a solid protection from direct and scattered laser beams. We take the guesswork out of selection and purchase of Ar ion, YAG, and YLF safety eyewear, so you can focus on using the system. |
 |
TSI's PIV Mount Kits provide a user-friendly and rugged but precise mounting base for your PIV camera(s). Easy adjustment and long-term stability are the key features of the TSI PIV Mount Kits. |
 |
TSI Rails provide the flexibility in a sturdy support system needed for any PIV system. Various lengths are available, to customise the system to the cameras and light sheet optics used. |
 |
Remote Focus MechanismTSI Model 640050/1-R series of Remote Focus Mechanism provides the remote and precise adjustment of camera focusing tot he measurement plane in PIV/PLIF measurements |
SERVICE INFORMATION
APPLICATION NOTESTECHNICAL NOTES
|