PLIF SYSTEM CONCENTRATION AND VELOCITY MEASUREMENT
The TSI PowerView based Global Liquid Concentration Analyzer (GLCA) and Global Liquid Mixing Analyzer (GLMA) are designed to meet the research needs of anyone needing a fully integrated, turn-key system that provides global species measurements in mixing, materials processing, heat/mass transfer, and other liquid based environments. Both systems use planar laser-induced fluorescence (PLIF) to provide global concentration measurement of the species of interest in the laser sheet region. Both systems are composed of three integrated sub-systems: the Illumination System, the Imaging System, and the Display and Analysis System. The only difference is that the GLMA system provides simultaneous concentration AND velocity fields, to fully characterize micro-fluidic mixers, reactors, and numerous other processes. GLMA and GLCA systems are composed of three sub-systems: The Illumination Sub-system includes a Nd:YAG laser, lenses, and beam delivery optics to get the light sheet where you need it. The Imaging Sub-system features one (GLCA) or two (GLMA) TSI PowerView cameras with the right resolution, sensitivity, and speed required for your application. The laser and camera are controlled by a TSI LaserPulse Synchronizer, which is fully integrated into the revolutionary Insight 3G Global Imaging software platform, which not only provides data analysis and display capabilities, but also directly controls the hardware components for simple system operation.
features and benefits
- Provides global measurements of scalar quantities such as concentration and temperature
- Advanced analysis algorithms to account for camera noise, background signals, spatial variations in laser sheet intensity, temporal variations in laser pulse energy
- User-programmable image analysis schemes for maximum experimental flexibility
- Full range of camera support, including all TSI intensified and un-intensified cameras
- Seamless integration with TSI PIV systems for simultaneous global velocity measurements
applications
- Mixing studies
- Temperature Measurements
- Concentration Measurements
 |
TSI Computers integrate the latest advances in computer technology, including processing and memory storage, in order to provide the fastest, most flexible PIV and/or PLIF system available. |
 |
INSIGHT™ 3G-PIVLIF software package processes PIV and PLIF image capture, analysis and display software on .NET platform. |
 |
INSIGHT™ 3G-2DTR software package process PIV image capture, analysis and display software on .NET platform |
 |
INSIGHT™ 3G-Global software package process Stereo PIV, PLIF and Global Spray image capture, analysis and display software on .NET platform
|
 |
TSI LASERPULSE Mini-YAG Laser Model YAG120-BSL |
 |
TSI LASERPULSE YAG Laser Model YAG190-BSL |
 |
TSI LASERPULSE Mini-YAG Laser Model YAG30-15 |
 |
TSI LASERPULSE Mini-YAG Laser Model YAG50-15 |
 |
The LASERPULSE Synchronizer Model 610035 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications. |
 |
TSI’s LASERPULSE Light Arm is an articulated arm that offers flexibility in delivering the light sheet for PIV measurements or for other high energy laser applications. |
 |
Laser light sheet optics from TSI provide flexibility in the light sheet divergence angle and the beam waist location via careful selection of focal lengths. for PIV and PLIF applications. |
 |
TSI's POWERVIEW™ 1.4MP Camera offers 1376 × 1040 pixel resolution and 12-bit intensity dynamic range, short frame straddling times, and long exposure times for PIV and PLIF applications. |
.jpg) |
TSI POWERVIEW™ Plus 11MP Camera is a multi-bit, 11-megapixel, digital CCD camera designed exclusively for global flow measurements. |
.jpg) |
TSI POWERVIEW™ Plus 2MP Camera is a multi-bit, 2-megapixel, digital CCD camera designed exclusively for global flow measurements. |
.jpg) |
TSI POWERVIEW™ Plus 4MP Camera is a multi-bit, 4-megapixel, digital CCD camera designed exclusively for global flow measurements. |
 |
POWERVIEW™ Plus HS-200 Camera has 640 × 480 pixel resolution, 12-bit intensity dynamic range, along with high image capture rates up to 500 frames per second. |
 |
TSI offers a full range of optical filters, which are a critically important component of PIV and PLIF system, ensuring that the correct wavelength of light is collected by the CCD camera and that other wavelengths are rejected. |
 |
High output fog generator for LDV and PIV seeding with large scale wind tunnels, HVAC equipment, and other high flow devices. |
 |
TSI Laser Power Meters provide a convenient and accurate way to measure Ar ion beam powers, to keep your LDV or PDPA system running at peak efficiency. |
 |
TSI Laser Laser Safety Goggles provide a solid protection from direct and scattered laser beams. We take the guesswork out of selection and purchase of Ar ion, YAG, and YLF safety eyewear, so you can focus on using the system. |
 |
TSI's PIV Mount Kits provide a user-friendly and rugged but precise mounting base for your PIV camera(s). Easy adjustment and long-term stability are the key features of the TSI PIV Mount Kits. |
 |
The Oil Droplet Generator (TSI Model 9307) is used to produce large quantities of oil droplets for seeding flows when making PIV or LDV measurements. The large droplet output is especially useful for seeding high-speed flows. |
 |
TSI Rails provide the flexibility in a sturdy support system needed for any PIV system. Various lengths are available, to customise the system to the cameras and light sheet optics used. |
 |
Remote Focus MechanismTSI Model 640050/1-R series of Remote Focus Mechanism provides the remote and precise adjustment of camera focusing tot he measurement plane in PIV/PLIF measurements |
 |
TSI offers a full range of seed particles to satisfy even the most difficult measurement requirements. Available in a full range of materials and sizes, TSI seed particles maximize the potential of PIV and LDV systems. |
 |
TSI's Model 9302 single-jet atomizer generates a polydisperse aerosol stream from a compressed air source. External pressure control and a flexible outlet tube allow the user to put the right amount of aerosol right where its needed. |
 |
The Six-Jet atomizer from TSI is used to generate a polydisperse aerosol in high concentrations, which can be used as seed particles for PIV and LDV measurements. External controls adjust the number of active jets and dilution air flow rate. |
 |
Traverse accessories help the user get the most productivity out of their TSI traverse, while enhancing safety of operation. |
 |
Single Axis (1D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. These traverses are also used for capturing size and velocity profiles in a flow with a FLOWSIZER™ |
.jpg) |
TSI T2D and T2DE Two Axis (2D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis System. |
 |
Three Axis (3D) Heavy-duty Traverse Systems are used for capturing size and velocity profiles in a flow with a three-component FLOWSIZER™ software-based LDV or phase Doppler system. |
 |
Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with TSI INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. |
 |
Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. |
BROCHURESPOSTERSSPEC SHEETSSERVICE INFORMATION
APPLICATION NOTESTECHNICAL NOTES
|
|